20% OFF shipping at www.letsgoget.info on orders over $79 + up to 10% OFF products
www.letsgoget.info
home > Wilkins 114-375 | Reduced Pressure Backflow Assembly, Non-Potable > Wilkins 114-375 | Reduced Pressure Backflow Assembly, Non-Potable
download picture
Wilkins 114-375 | Reduced Pressure Backflow Assembly, Non-PotableThe Wilkins 114 375 is a reduced pressure principle backflow assembly engineered for non potable irrigation applications, providing reliable protection against backsiphonage and backpressure contamination. Key Specifications: Size: 1 1 4 Inches Maximum Working Water Pressure: 175 PSI Maximum Working Water Temperature: 180F Notable Certifications: ASSE 1013, cUPC, CSA B64. 4 End Connections: Threaded FNPT Other Related Variants: 112 375: 1 1 2 Inches
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

The Wilkins 114-375 is a reduced pressure principle backflow assembly engineered for non-potable irrigation applications, providing reliable protection against backsiphonage and backpressure contamination.

 

Key Specifications:

  • Size: 1 1/4 Inches
  • Maximum Working Water Pressure: 175 PSI
  • Maximum Working Water Temperature: 180°F
  • Notable Certifications: ASSE 1013, cUPC, CSA B64.4
  • End Connections: Threaded FNPT

 

Other Related Variants:

  • 112-375: 1 1/2 Inches model size
  • 12-375: 1/2 Inches version
  • 1-375: 1 Inches version
  • 2-375: 2 Inches model size
  • 34-375: 3/4 Inches version

 

Materials:

  • Reinforced Nylon housing
  • Stainless Steel fasteners (300 Series)
  • Silicone elastomers
  • Buna Nitrile elastomers
  • Delrin internals
  • Nylon internals
  • Stainless Steel springs (300 Series)
  • Cast Bronze ball valves (ASTM B 584)
  • Stainless Steel struts (300 Series)

 

Typical Installation:

Local codes shall govern installation requirements. To be installed in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12 inches (305mm) and a maximum of 30 inches (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged.

 

Standards Compliance:

ASSE Listed 1013; cUPC Listed; CSA Certified B64.4; AWWA compliant C511; Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California

 

Features & Benefits:

  • Backflow Protection: Protects potable water supply against both backsiphonage and backpressure of contaminated water in irrigation systems where a potential health hazard exists.
  • Durable Construction: Reinforced nylon body with stainless steel fasteners and silicone elastomers ensures long-lasting performance and corrosion resistance rated to 350 PSI hydrostatic test pressure.
  • Versatile Configuration: Available with optional full port QT ball valves, street elbows, strainer, air gap adapter, and test fittings for customized installation requirements.
  • High Temperature Rating: Rated for continuous operation up to 180°F maximum working water temperature for demanding irrigation applications.

 

FAQ

 

Q: What is the proper mounting height for the Zurn 114-375 backflow preventer?

A: The assembly must be mounted at a minimum of 12 inches and a maximum of 30 inches above adequate drains with sufficient side clearance for testing and maintenance.

Q: Can the Wilkins 114-375 be used for potable water applications?

A: No, this model is designed for non-potable water applications only, specifically for irrigation water lines.

Q: What certifications does the Zurn Wilkins 114-375 carry?

A: The unit is ASSE Listed 1013, cUPC Listed, CSA Certified B64.4, AWWA compliant C511, and approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California.

 

NOTICE: Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system.

"Hydrate Everyone, Everywhere!" BottleFillingStations.com | Contact us

Wilkins 114-375 | Reduced Pressure Backflow Assembly, Non-Potable

Item no : 80768150509
sold recently : Login >>
US$ 645.50
Pay in 4 interest-free payments of $161.38 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 24 - Jun 29

Enjoy 20% off shipping

US$ 645.50

1-11

US$ 580.95

12-35

US$ 451.85

36-59

US$ 387.30

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches