20% OFF shipping at www.letsgoget.info on orders over $79 + up to 10% OFF products
www.letsgoget.info
home > Wilkins 34-975XL3AG | 3/4" RP Backflow Preventer with Air Gap > Wilkins 34-975XL3AG | 3/4" RP Backflow Preventer with Air Gap
download picture
Wilkins 34-975XL3AG | 3/4" RP Backflow Preventer with Air GapNOTICE: Product images may vary from the actual item due to differences in size or configuration options. The Wilkins 34 975XL3AG is a lead free reduced pressure principle backflow preventer with air gap accessories, designed for compact potable water protection where health hazards exist. Key Specifications: Size: 3 4 Inches Maximum Working Pressure: 175 PSI Maximum Working Temperature: 180F Notable Certifications: ASSE 1013, cUPC, CSA B64. 4 End
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

NOTICE: Product images may vary from the actual item due to differences in size or configuration options.

The Wilkins 34-975XL3AG is a lead-free reduced pressure principle backflow preventer with air gap accessories, designed for compact potable water protection where health hazards exist.

 

Key Specifications:

  • Size: 3/4 Inches
  • Maximum Working Pressure: 175 PSI
  • Maximum Working Temperature: 180°F
  • Notable Certifications: ASSE 1013, cUPC, CSA B64.4
  • End Connections: FNPT Threaded

 

Other Related Variants:

  • 112-975XL3: 1/2 Inch size
  • 1-975XL3: 1 Inch size
  • 114-975XL3: 1 1/4 Inch size
  • 12-975XL3: 1 1/2 Inch size
  • 2-975XL3: 2 Inch size

 

Materials:

  • Low Lead Cast Bronze body (ASTM B 584)
  • Low Lead Cast Bronze access covers (ASTM B 584)
  • Noryl™ internal polymers
  • Stainless Steel springs (300 Series)
  • Stainless Steel fasteners (300 Series)
  • Silicone elastomers (FDA Approved)
  • Buna Nitrile elastomers (FDA Approved)
  • Stainless Steel ball valve handles

 

Typical Installation:

Designed for installation on potable water lines to protect against both backsiphonage and backpressure of contaminated water into the potable water supply. Assembly shall be mounted at a minimum of 12 inches and a maximum of 30 inches above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. Ideal for use where lead-free valves are required and assembly shall provide protection where a potential health hazard exists.

 

Standards Compliance:

ASSE Listed 1013; cUPC Listed; CSA Certified B64.4; UL Classified (less shut-off valves); C-UL Classified; AWWA Compliant C511; NSF/ANSI/CAN 61; NSF/ANSI/CAN 372; Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California

 

Features & Benefits:

  • Lead-Free Compliance: NSF/ANSI/CAN 372 certified with less than 0.25% weighted average lead content for safe potable water applications.
  • Dual Protection: Protects against both backsiphonage and backpressure with reduced pressure principle design for maximum safety.
  • Easy Maintenance Access: First and second checks accessible through single shared access cover without removing the relief valve or entire device from the line.
  • Compact Design with Air Gap: Includes air gap accessories (AG) for proper indoor installation compliance and space-efficient installation.

 

FAQ

 

Q: What is the minimum working water pressure required for the Zurn 34-975XL3AG?

A: The minimum working water pressure required is 25 PSI to ensure proper operation of the backflow preventer.

Q: Can this backflow preventer be installed outdoors without the air gap accessory?

A: Yes, the air gap accessory is specifically required for indoor installations. Outdoor installations do not require the air gap adapter but should have protective enclosure.

Q: How do I access the check valves for maintenance on the Wilkins 34-975XL3AG?

A: The first and second check valves are accessible through a single shared access cover from the top of the device, allowing maintenance without removing the relief valve or the entire assembly from the line.

 

NOTICE: Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system.

"Hydrate Everyone, Everywhere!" BottleFillingStations.com | Contact us

Wilkins 34-975XL3AG | 3/4" RP Backflow Preventer with Air Gap

Item no : 53495597917
sold recently : Login >>
US$ 537.00
Pay in 4 interest-free payments of $134.25 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Aug 1 - Aug 6

Enjoy 20% off shipping

US$ 537.00

1-11

US$ 483.30

12-35

US$ 375.90

36-59

US$ 322.20

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches