Shopping security
The ICS Triplex T9802 is a high-performance, dual-channel digital input module engineered for safety-critical environments. As part of the AADvance™ family, it provides reliable fault-tolerant performance for Safety Instrumented Systems (SIS) requiring SIL 3 compliance according to IEC 61508. The module is ideal for Emergency Shutdown (ESD), burner management, turbine control, and other high-integrity applications.
The T9802 integrates seamlessly into the Trusted™ TMR platform, leveraging Triple Modular Redundant (TMR) technology to ensure continuous operation even under hardware faults. Its robust design enables hot-swapping, allowing maintenance or module replacement without interrupting system operation.
Redundant Architecture: Dual-channel input with 2-out-of-3 (2oo3) voting logic ensures fault tolerance and high availability.
Safety Certification: SIL 3 certified for critical safety loops.
Isolation: High-voltage separation between channels and power supply protects the module and connected devices.
Installation: DIN rail mountable for efficient cabinet integration.
| Feature | Specification |
|---|---|
| Model | T9802 |
| Input Channels | 16 isolated digital channels |
| Redundancy | Dual-channel architecture with TMR voting |
| Isolation Voltage | 2500 V RMS |
| Input Voltage | 24 VDC |
| Input Current | 2 A per channel |
| Input Impedance | 47 kΩ |
| Response Time | < 2 ms per channel |
| Common Mode Rejection | > 60 dB |
| Operating Temperature | –40°C to +85°C |
| Storage Temperature | –40°C to +85°C |
| Humidity | 5–95% RH, non-condensing |
| Vibration Resistance | 5 g RMS, 10–500 Hz |
| Shock Resistance | 30 g, 11 ms half-sine |
| MTBF | >100 years |
| Protection Features | Short-circuit, open-circuit, and earth leakage detection |
2oo3 Voting Logic
Each input signal is processed across three independent circuits, ensuring that a single hardware fault does not disrupt module operation.
Advanced Line Monitoring
Detects field-side anomalies including open circuits, short circuits, and insulation breakdown.
High-Resolution SOE Logging
Integrated Sequence of Events (SOE) allows timestamped tracking of output changes for detailed incident analysis.
Active/Standby Support
Pairs with companion modules for seamless online testing, maintenance, and redundancy without interrupting process outputs.
Emergency Shutdown (ESD) systems
Burner Management Systems (BMS)
Turbine and compressor safety control
Nuclear power plant monitoring
Chemical and oil & gas process protection
Q: Can the module be serviced while the system is active?
A: Yes, it supports hot-swapping, allowing replacement without downtime.
Q: What safety integrity level does the T9802 support?
A: Certified for SIL 3 operations per IEC 61508.
Q: How does the module detect wiring faults?
A: Through comprehensive line monitoring, it identifies open circuits, shorts, and insulation failures.
Q: Is the module suitable for harsh environments?
A: Yes, it operates from –40°C to +85°C, resists vibration up to 5 g RMS, and meets high EMI/RFI immunity standards.
Ships within 48 hours · Estimated delivery Jul 1 - Jul 6
US$40
Get nowSign up to your membership to get coupons up to
15%
Get nowOpportunity to enjoy order discount up to 15% off
Top-Converting Item to Boost Your Average Order