Wilkins 34-975XL3SE | Reduced Pressure Principle Backflow PreventerThe Wilkins 34 975XL3SE is a lead free reduced pressure principle backflow preventer designed for compact potable water installations requiring protection against backsiphonage and backpressure contamination with 90 elbows included. Key Specifications: Size: 3 4 Inches Maximum Working Water Pressure: 175 PSI Maximum Working Water Temperature: 180F Notable Certifications: ASSE 1013, cUPC, CSA B64. 4 End Connections: FNPT threaded Other Related
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

The Wilkins 34-975XL3SE is a lead-free reduced pressure principle backflow preventer designed for compact potable water installations requiring protection against backsiphonage and backpressure contamination with 90° elbows included.

 

Key Specifications:

  • Size: 3/4 Inches
  • Maximum Working Water Pressure: 175 PSI
  • Maximum Working Water Temperature: 180°F
  • Notable Certifications: ASSE 1013, cUPC, CSA B64.4
  • End Connections: FNPT threaded

 

Other Related Variants:

  • 112-975XL3: 1 1/2 Inches model size
  • 114-975XL3: 1 1/4 Inches model size
  • 12-975XL3: 1/2 Inches model size
  • 1-975XL3: 1 Inches model size
  • 2-975XL3: 2 Inches model size

 

Materials:

  • Low Lead Cast Bronze body (ASTM B 584)
  • Low Lead Cast Bronze access covers (ASTM B 584)
  • Stainless Steel fasteners (300 Series)
  • Stainless Steel springs (300 Series)
  • Stainless Steel ball valve handles
  • Silicone elastomers (FDA Approved)
  • Buna Nitrile elastomers (FDA Approved)
  • Noryl™ polymers

 

Typical Installation:

Local codes shall govern installation requirements. To be installed in accordance with the manufacturers' instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a minimum of 12 inches (305mm) and a maximum of 30 inches (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged.

 

Standards Compliance:

ASSE Listed 1013; cUPC Listed; CSA Certified B64.4; UL Classified; C-UL Classified; AWWA Compliant C511; NSF/ANSI/CAN 61 & 372 compliant; Approved by Foundation for Cross Connection Control and Hydraulic Research at University of Southern California

 

Features & Benefits:

  • Lead-Free Compliance: Meets NSF/ANSI/CAN 372 with less than 0.25% weighted average lead content for safe potable water applications.
  • Dual Protection Design: Protects against both backsiphonage and backpressure contamination in potable water lines where potential health hazards exist.
  • Easy Maintenance Access: First and second checks accessible through single cover without removing relief valve or entire device from line.
  • Compact Installation Option: SE option includes 90° elbows for space-saving installations on potable water services.

 

FAQ

 

Q: What is the minimum working water pressure required for the Zurn 34-975XL3SE?

A: The minimum working water pressure for the Zurn 34-975XL3SE is 25 PSI to ensure proper operation of the reduced pressure principle assembly.

Q: Can this backflow preventer be installed outdoors?

A: Yes, the 34-975XL3SE can be installed outdoors within a protective enclosure. For indoor installations, an air gap adapter should be supplied.

Q: What size air gap adapter is needed for this model?

A: For the 3/4 inch 34-975XL3SE, the Model AG-8 air gap adapter is recommended for indoor installations.

 

NOTICE: Do not use with water that is unsafe or of unknown quality without adequate disinfection either before or after the system.

"Hydrate Everyone, Everywhere!" BottleFillingStations.com | Contact us

Wilkins 34-975XL3SE | Reduced Pressure Principle Backflow Preventer

Item no : 44730271043
sold recently : Login >>
US$ 477.98
Pay in 4 interest-free payments of $119.50 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 24 - Jun 29

Enjoy 20% off shipping

US$ 477.98

1-11

US$ 430.18

12-35

US$ 334.59

36-59

US$ 286.79

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches